Shelby Pointe
100 Rogers Lane, Shelby, OH 44875 · Richland County · CCN 365331 · 4193471313
All ratings are CMS Five-Star ratings from the October 1, 2026 release. “Not rated” means CMS did not publish a rating for this facility in that release.
Facility facts (CMS record)
| Legal business name | Shelby Pointe Llc |
|---|---|
| Ownership type | For profit - Corporation |
| Certified beds | 45 |
| Average residents per day | 43.5 |
| Provider type | Medicare and Medicaid |
| Certified since | 1976-03-08 |
| Chain | Jag Healthcare (9 facilities nationally) |
| Changed ownership in last 12 months | No |
| Sprinklers in all required areas | Partial |
Staffing (CMS record, hours per resident per day)
| Total nurse staffing (adjusted) | 3.99741 |
|---|---|
| RN staffing (adjusted) | 0.24414 |
| Total nurse staffing (reported) | 4.04366 |
| Total nursing staff turnover | 35.9% |
| RN turnover | 60% |
| Administrators who left in the past year | 0 |
How this facility's record has changed
CMS overall rating at each monthly data release, as published at the time. Points are releases, not survey dates.
| CMS release | Overall | Health inspection | Staffing | Quality measures | Total nurse staffing (hrs / resident / day, adjusted) | Nurse turnover |
|---|---|---|---|---|---|---|
| 2019-04-09 | 4 | 4 | 2 | 2 | 3.50868 | — |
| 2019-07-09 | 4 | 4 | 2 | 3 | 3.63236 | — |
| 2019-10-09 | 5 | 5 | 2 | 3 | 3.71577 | — |
| 2020-01-09 | 4 | 5 | 1 | 3 | 3.32006 | — |
| 2020-04-09 | 4 | 4 | 2 | 2 | 3.5896 | — |
| 2020-07-09 | 4 | 4 | 2 | 2 | 3.5896 | — |
| 2020-10-09 | 4 | 4 | 2 | 2 | 3.57966 | — |
| 2021-01-27 | 4 | 4 | 2 | 2 | 3.73593 | — |
| 2021-04-27 | 4 | 5 | 2 | 1 | 3.69631 | — |
| 2021-07-27 | 4 | 5 | 2 | 1 | 3.69433 | — |
| 2021-10-27 | 3 | 5 | 1 | 1 | 3.29505 | — |
| 2022-01-27 | 2 | 4 | 1 | 1 | 2.98555 | — |
| 2022-04-27 | 2 | 4 | 1 | 1 | 2.79189 | — |
| 2022-07-27 | 2 | 4 | 1 | 1 | 3.29452 | — |
| 2022-10-27 | 3 | 4 | 1 | 3 | 3.3637 | — |
| 2023-01-02 | 3 | 4 | 1 | 3 | 3.27856 | — |
| 2023-04-26 | 2 | 3 | 1 | 4 | 2.85661 | — |
| 2023-07-25 | 3 | 3 | 2 | 4 | 3.22893 | — |
| 2023-10-02 | 2 | 3 | 1 | 4 | 3.28953 | — |
| 2024-01-31 | 2 | 3 | 1 | 4 | 3.19866 | — |
| 2024-04-25 | 3 | 3 | 2 | 3 | 3.19866 | — |
| 2024-07-31 | 3 | 3 | 2 | 3 | 3.30808 | — |
| 2024-10-30 | 2 | 3 | 1 | 3 | 2.65606 | — |
| 2025-02-26 | 3 | 4 | 1 | 3 | 2.79609 | — |
| 2025-04-30 | 2 | 3 | 1 | 3 | 3.05179 | — |
| 2025-07-30 | 2 | 3 | 1 | 4 | 2.91701 | — |
| 2025-11-20 | 3 | 3 | 1 | 5 | 2.83447 | — |
| 2026-01-14 | 4 | 4 | 1 | 5 | 2.83447 | — |
| 2026-04-29 | 5 | 4 | 2 | 5 | 3.44669 | — |
| 2026-10-28 | 5 | 4 | 3 | 5 | 3.99741 | — |
Notable events in the record
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 3 → 4 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 4 → 3 stars
CMS overall rating changed: 5 → 4 stars
CMS overall rating changed: 4 → 5 stars
Inspection citations (44)
Survey cycles on record: Cycle 1: health survey 2025-01-02 (8 health deficiencies), fire safety survey 2025-01-02 (9); Cycle 2: health survey 2023-10-12 (5 health deficiencies), fire safety survey 2023-10-12 (5); Cycle 3: health survey 2021-08-05 (2 health deficiencies), fire safety survey 2021-08-05 (15)
2025-01-02 — Health survey (Health): 8 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0575 | Resident Rights Deficiencies | Post a list of names, addresses, and telephone numbers of all pertinent State agencies and advocacy groups and a statement that the resident may file a complaint with the State Survey Agency. | C | Deficient, Provider has plan of correction (2025-01-20) |
| F0641 | Resident Assessment and Care Planning Deficiencies | Ensure each resident receives an accurate assessment. | B | Deficient, Provider has plan of correction (2025-01-20) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | D | Deficient, Provider has date of correction (2025-02-21) |
| F0758 | Pharmacy Service Deficiencies | Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited. | D | Deficient, Provider has date of correction (2025-02-21) |
| F0838 | Administration Deficiencies | Conduct and document a facility-wide assessment to determine what resources are necessary to care for residents competently during both day-to-day operations (including nights and weekends) and emergencies. | C | Deficient, Provider has plan of correction (2025-01-20) |
| F0881 | Infection Control Deficiencies | Implement a program that monitors antibiotic use. | D | Deficient, Provider has date of correction (2025-02-21) |
| F0914 | Environmental Deficiencies | Provide bedrooms that don't allow residents to see each other when privacy is needed. | D | Deficient, Provider has date of correction (2025-02-21) |
| F0921 | Environmental Deficiencies | Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public. | F | Deficient, Provider has date of correction (2025-02-21) |
2025-01-02 — Fire safety survey (Fire Safety): 9 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0345 | Smoke Deficiencies | Have approved installation, maintenance and testing program for fire alarm systems. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0372 | Smoke Deficiencies | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0753 | Miscellaneous Deficiencies | Have restrictions on the use of highly flammable decorations. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0781 | Miscellaneous Deficiencies | Have restrictions on the use of portable space heaters. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0916 | Gas, Vacuum, and Electrical Systems Deficiencies | Have a battery powered remote alarm panel in a location accessible by operating personnel. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2025-02-21) |
| K0920 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure proper usage of power strips and extension cords. | F | Deficient, Provider has date of correction (2025-02-21) |
2023-10-12 — Fire safety survey (Fire Safety): 5 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| E0015 | Emergency Preparedness Deficiencies | Address subsistence needs for staff and patients. | F | Deficient, Provider has date of correction (2023-11-30) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | F | Deficient, Provider has date of correction (2023-11-30) |
| K0372 | Smoke Deficiencies | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | F | Deficient, Provider has date of correction (2023-11-30) |
| K0511 | Services Deficiencies | Have properly installed electrical wiring and gas equipment. | F | Deficient, Provider has date of correction (2023-11-30) |
| K0741 | Miscellaneous Deficiencies | Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. | F | Deficient, Provider has date of correction (2023-11-30) |
2023-10-12 — Health survey (Health): 5 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0558 | Resident Rights Deficiencies | Reasonably accommodate the needs and preferences of each resident. | E | Deficient, Provider has date of correction (2023-11-30) |
| F0644 | Resident Assessment and Care Planning Deficiencies | Coordinate assessments with the pre-admission screening and resident review program; and referring for services as needed. | D | Deficient, Provider has date of correction (2023-11-30) |
| F0800 | Nutrition and Dietary Deficiencies | Provide each resident with a nourishing, palatable, well-balanced diet that meets his or her daily nutritional and special dietary needs. | E | Deficient, Provider has date of correction (2023-11-30) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | F | Deficient, Provider has date of correction (2023-11-30) |
| F0908 | Environmental Deficiencies | Keep all essential equipment working safely. | D | Deficient, Provider has date of correction (2023-11-30) |
2021-08-05 — Fire safety survey (Fire Safety): 15 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| E0037 | Emergency Preparedness Deficiencies | Establish staff and initial training requirements. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0223 | Egress Deficiencies | Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0225 | Egress Deficiencies | Have stairways and smokeproof enclosures used as exits that meet safety requirements. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0362 | Smoke Deficiencies | Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0511 | Services Deficiencies | Have properly installed electrical wiring and gas equipment. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0525 | Services Deficiencies | Enure that solid fuel-burning fireplaces are not in patient sleeping areas. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0741 | Miscellaneous Deficiencies | Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0781 | Miscellaneous Deficiencies | Have restrictions on the use of portable space heaters. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0914 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2021-11-18) |
| K0920 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure proper usage of power strips and extension cords. | E | Deficient, Provider has date of correction (2021-11-18) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | Have proper medical gas storage and administration areas. | E | Deficient, Provider has date of correction (2021-11-18) |
2021-08-05 — Health survey (Health): 2 citations, most severe scope/severity: D
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0758 | Pharmacy Service Deficiencies | Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited. | D | Deficient, Provider has date of correction (2021-11-18) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | D | Deficient, Provider has date of correction (2021-11-18) |
Deficiency descriptions, categories and scope/severity codes are reproduced from CMS records. Scope/severity runs A (least) to L (most severe); J, K and L indicate immediate jeopardy findings in the CMS coding system.