Southwood At Norwell Nursing Ctr
501 Cordwainer Drive, Norwell, MA 02061 · Plymouth County · CCN 225597 · 7819827450
All ratings are CMS Five-Star ratings from the October 1, 2026 release. “Not rated” means CMS did not publish a rating for this facility in that release.
Facility facts (CMS record)
| Legal business name | Southwood At Norwell Nursing Center |
|---|---|
| Ownership type | For profit - Partnership |
| Certified beds | 142 |
| Average residents per day | 122 |
| Provider type | Medicare and Medicaid |
| Certified since | 1993-10-28 |
| Changed ownership in last 12 months | No |
| Sprinklers in all required areas | Yes |
Staffing (CMS record, hours per resident per day)
| Total nurse staffing (adjusted) | 4.51777 |
|---|---|
| RN staffing (adjusted) | 0.87733 |
| Total nurse staffing (reported) | 4.01298 |
| Total nursing staff turnover | 27% |
| RN turnover | 33.3% |
| Administrators who left in the past year | 0 |
How this facility's record has changed
CMS overall rating at each monthly data release, as published at the time. Points are releases, not survey dates.
| CMS release | Overall | Health inspection | Staffing | Quality measures | Total nurse staffing (hrs / resident / day, adjusted) | Nurse turnover |
|---|---|---|---|---|---|---|
| 2019-04-09 | 3 | 2 | 4 | 3 | 3.69323 | — |
| 2019-07-09 | 2 | 2 | 3 | 3 | 3.54757 | — |
| 2019-10-09 | 1 | 1 | 3 | 3 | 3.50817 | — |
| 2020-01-09 | 2 | 1 | 5 | 3 | 4.09646 | — |
| 2020-04-09 | 2 | 1 | 4 | 3 | 3.71225 | — |
| 2020-07-09 | 2 | 1 | 4 | 4 | 3.71225 | — |
| 2020-10-09 | 2 | 1 | 4 | 4 | 3.74312 | — |
| 2021-01-27 | 2 | 1 | 4 | 3 | 3.96203 | — |
| 2021-04-27 | 2 | 1 | 5 | 4 | 4.26316 | — |
| 2021-07-27 | 2 | 1 | 5 | 4 | 4.05462 | — |
| 2021-10-27 | 2 | 1 | 4 | 4 | 3.82424 | — |
| 2022-01-27 | 1 | 1 | 3 | 4 | 3.57225 | — |
| 2022-04-27 | 3 | 2 | 3 | 5 | 3.3872 | — |
| 2022-07-27 | 3 | 2 | 3 | 5 | 3.48731 | — |
| 2022-10-27 | 3 | 2 | 4 | 5 | 3.72914 | — |
| 2023-01-02 | 3 | 2 | 4 | 5 | 3.77729 | — |
| 2023-04-26 | 3 | 2 | 4 | 5 | 4.00467 | — |
| 2023-07-25 | 3 | 2 | 4 | 5 | 4.04555 | — |
| 2023-10-02 | 3 | 2 | 4 | 5 | 4.01241 | — |
| 2024-01-31 | 4 | 3 | 4 | 5 | 3.94058 | — |
| 2024-04-25 | 5 | 3 | 5 | 5 | 3.94058 | — |
| 2024-07-31 | 4 | 3 | 4 | 5 | 3.99805 | — |
| 2024-10-30 | 4 | 3 | 4 | 5 | 4.08722 | — |
| 2025-02-26 | 4 | 3 | 4 | 5 | 3.82715 | — |
| 2025-04-30 | 5 | 4 | 5 | 5 | 4.32383 | — |
| 2025-07-30 | 5 | 5 | 4 | 5 | 4.12312 | — |
| 2025-11-20 | 5 | 5 | 4 | 5 | 4.13803 | — |
| 2026-01-14 | 5 | 5 | 4 | 5 | 4.13803 | — |
| 2026-04-29 | 5 | 5 | 4 | 5 | 4.34966 | — |
| 2026-10-28 | 5 | 5 | 5 | 5 | 4.51777 | — |
Notable events in the record
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 5 → 4 stars
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 3 → 4 stars
CMS overall rating changed: 1 → 3 stars
CMS overall rating changed: 2 → 1 stars
CMS overall rating changed: 1 → 2 stars
CMS overall rating changed: 2 → 1 stars
CMS overall rating changed: 3 → 2 stars
Inspection citations (27)
Survey cycles on record: Cycle 1: health survey 2026-01-02 (2 health deficiencies), fire safety survey 2026-01-02 (7); Cycle 2: health survey 2024-12-04 (0 health deficiencies), fire safety survey 2024-12-04 (11); Cycle 3: health survey 2023-09-29 (7 health deficiencies), fire safety survey 2023-09-29 (0)
2026-01-02 — Health survey (Health): 2 citations, most severe scope/severity: D
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0695 | Quality of Life and Care Deficiencies | Provide safe and appropriate respiratory care for a resident when needed. | D | Deficient, Provider has date of correction (2026-01-26) |
| F0761 | Pharmacy Service Deficiencies | Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs. | D | Deficient, Provider has date of correction (2026-01-26) |
2026-01-02 — Fire safety survey (Fire Safety): 7 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0311 | Smoke Deficiencies | Have an enclosure around a vertical opening shaft. | E | Deficient, Provider has date of correction (2026-03-20) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | E | Deficient, Provider has date of correction (2026-03-20) |
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | D | Deficient, Provider has date of correction (2026-03-20) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | E | Deficient, Provider has date of correction (2026-03-20) |
| K0372 | Smoke Deficiencies | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | F | Deficient, Provider has date of correction (2026-03-20) |
| K0374 | Smoke Deficiencies | Install smoke barrier doors that can resist smoke for at least 20 minutes. | F | Deficient, Provider has date of correction (2026-03-20) |
| K0711 | Miscellaneous Deficiencies | Provide a written emergency evacuation plan. | E | Deficient, Provider has date of correction (2026-03-20) |
2024-12-04 — Fire safety survey (Fire Safety): 11 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| E0004 | Emergency Preparedness Deficiencies | Develop and maintain an Emergency Preparedness Program (EP). | F | Deficient, Provider has date of correction (2025-01-31) |
| E0013 | Emergency Preparedness Deficiencies | Develop Emergency Preparedness policies and procedures. | F | Deficient, Provider has date of correction (2025-01-31) |
| E0029 | Emergency Preparedness Deficiencies | Develop a communication plan. | F | Deficient, Provider has date of correction (2025-01-31) |
| E0036 | Emergency Preparedness Deficiencies | Establish emergency prep training and testing. | F | Deficient, Provider has date of correction (2025-01-31) |
| K0291 | Egress Deficiencies | Install emergency lighting that can last at least 1 1/2 hours. | D | Deficient, Provider has date of correction (2025-01-31) |
| K0341 | Smoke Deficiencies | Install a fire alarm system that can be heard throughout the facility. | D | Deficient, Provider has date of correction (2025-01-31) |
| K0351 | Smoke Deficiencies | Install an approved automatic sprinkler system. | F | Deficient, Provider has date of correction (2025-01-31) |
| K0361 | Smoke Deficiencies | Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the corridor are properly protected. | D | Deficient, Provider has date of correction (2025-01-31) |
| K0511 | Services Deficiencies | Have properly installed electrical wiring and gas equipment. | F | Deficient, Provider has date of correction (2025-01-31) |
| K0911 | Gas, Vacuum, and Electrical Systems Deficiencies | Meet requirements for the installation and maintenance of electrical systems. | E | Deficient, Provider has date of correction (2025-01-31) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | E | Deficient, Provider has date of correction (2025-01-31) |
2023-09-29 — Health survey (Health): 7 citations, most severe scope/severity: E
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0655 | Resident Assessment and Care Planning Deficiencies | Create and put into place a plan for meeting the resident's most immediate needs within 48 hours of being admitted | D | Deficient, Provider has date of correction (2023-11-06) |
| F0656 | Resident Assessment and Care Planning Deficiencies | Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured. | D | Deficient, Provider has date of correction (2023-11-06) |
| F0658 | Resident Assessment and Care Planning Deficiencies | Ensure services provided by the nursing facility meet professional standards of quality. | E | Deficient, Provider has date of correction (2023-11-06) |
| F0695 | Quality of Life and Care Deficiencies | Provide safe and appropriate respiratory care for a resident when needed. | D | Deficient, Provider has date of correction (2023-11-06) |
| F0740 | Quality of Life and Care Deficiencies | Ensure each resident must receive and the facility must provide necessary behavioral health care and services. | E | Deficient, Provider has date of correction (2023-11-06) |
| F0849 | Administration Deficiencies | Arrange for the provision of hospice services or assist the resident in transferring to a facility that will arrange for the provision of hospice services. | D | Deficient, Provider has date of correction (2023-11-06) |
| F0919 | Environmental Deficiencies | Make sure that a working call system is available in each resident's bathroom and bathing area. | E | Deficient, Provider has date of correction (2023-11-06) |
Deficiency descriptions, categories and scope/severity codes are reproduced from CMS records. Scope/severity runs A (least) to L (most severe); J, K and L indicate immediate jeopardy findings in the CMS coding system.