2026-10-28
CMS overall rating changed: 2 → 1 stars
2026-04-29
CMS overall rating changed: 3 → 2 stars
2025-07-30
CMS overall rating changed: 4 → 3 stars
2025-02-26
Ownership type changed: For profit - Partnership → For profit - Corporation
2024-10-30
CMS overall rating changed: 5 → 4 stars
2024-01-31
CMS overall rating changed: 4 → 5 stars
2023-01-02
CMS overall rating changed: 3 → 4 stars
2022-07-27
CMS overall rating changed: 4 → 3 stars
2022-04-27
CMS overall rating changed: 5 → 4 stars
2021-10-27
CMS abuse icon removed
2021-10-27
CMS overall rating changed: 4 → 5 stars
2021-04-27
CMS abuse icon added
2021-04-27
CMS overall rating changed: 5 → 4 stars
2019-10-09
Ownership type changed: For profit - Individual → For profit - Partnership
2019-10-09
CMS overall rating changed: 4 → 5 stars
The complete citation record as published by CMS: the current CMS release plus CMS's own published monthly archives. Where the current record carries the full deficiency text it is shown; older citations show the tag and its CMS category — follow the tag link for the CMS definition.
Survey cycles on record: Cycle 1: health survey 2025-11-19 (12 health deficiencies), fire safety survey 2025-11-19 (11); Cycle 2: health survey 2024-07-31 (13 health deficiencies), fire safety survey 2024-07-31 (17); Cycle 3: health survey 2023-05-10 (6 health deficiencies), fire safety survey 2023-05-10 (11)
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| E0026 | Emergency Preparedness Deficiencies | Establish roles under a Waiver declared by secretary. | F | Deficient, Provider has date of correction (2025-09-26) |
| K0211 | Egress Deficiencies | Keep aisles, corridors, and exits free of obstruction in case of emergency. | D | Deficient, Provider has date of correction (2025-09-27) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | D | Deficient, Provider has date of correction (2025-10-02) |
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | D | Deficient, Provider has date of correction (2025-09-26) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2025-10-03) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | D | Deficient, Provider has date of correction (2025-10-03) |
| K0372 | Smoke Deficiencies | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | D | Deficient, Provider has date of correction (2025-10-15) |
| K0500 | Services Deficiencies | Meet other general requirements that are deficient. | D | Deficient, Provider has date of correction (2025-09-30) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | D | Deficient, Provider has date of correction (2025-10-13) |
| K0761 | Miscellaneous Deficiencies | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | D | Deficient, Provider has date of correction (2025-10-06) |
| K0921 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure that testing and maintenance of electrical equipment is performed. | D | Deficient, Provider has date of correction (2025-10-06) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| F0583 | Resident Rights Deficiencies | Keep residents' personal and medical records private and confidential. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0584 | Resident Rights Deficiencies | Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely. | E | Deficient, Provider has date of correction (2026-01-30) |
| F0610 | Freedom from Abuse, Neglect, and Exploitation Deficiencies | Respond appropriately to all alleged violations. | D | Deficient, Provider has date of correction (2025-12-24) |
| F0656 | Resident Assessment and Care Planning Deficiencies | Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0657 | Resident Assessment and Care Planning Deficiencies | Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0684 | Quality of Life and Care Deficiencies | Provide appropriate treatment and care according to orders, resident’s preferences and goals. | D | Deficient, Provider has date of correction (2025-12-24) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | D | Deficient, Provider has date of correction (2026-01-30) |
| F0757 | Pharmacy Service Deficiencies | Ensure each resident’s drug regimen must be free from unnecessary drugs. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0867 | Administration Deficiencies | Set up an ongoing quality assessment and assurance group to review quality deficiencies and develop corrective plans of action. | E | Deficient, Provider has date of correction (2026-01-30) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | E | Deficient, Provider has date of correction (2025-12-24) |
| F0940 | Administration Deficiencies | Develop, implement, and/or maintain an effective training program for all new and existing staff members. | E | Deficient, Provider has date of correction (2025-12-24) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| E0026 | Emergency Preparedness Deficiencies | | F | Deficient, Provider has no plan of correction |
| K0211 | | | D | Deficient, Provider has no plan of correction |
| K0321 | Smoke Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0324 | Smoke Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0353 | Smoke Deficiencies | | F | Deficient, Provider has no plan of correction |
| K0363 | Smoke Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0372 | Smoke Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0500 | Services Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0712 | Miscellaneous Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0761 | Miscellaneous Deficiencies | | D | Deficient, Provider has no plan of correction |
| K0921 | Gas, Vacuum, and Electrical Systems Deficiencies | | D | Deficient, Provider has no plan of correction |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| E0006 | Emergency Preparedness Deficiencies | Conduct risk assessment and an All-Hazards approach. | F | Deficient, Provider has date of correction (2024-08-05) |
| E0024 | Emergency Preparedness Deficiencies | Establish policies and procedures for volunteers. | F | Deficient, Provider has date of correction (2024-08-05) |
| E0029 | Emergency Preparedness Deficiencies | Develop a communication plan. | F | Deficient, Provider has date of correction (2024-08-05) |
| K0163 | Construction Deficiencies | Install noncombustible or limited-combustible interior walls. | F | Deficient, Provider has date of correction (2024-08-05) |
| K0211 | Egress Deficiencies | Keep aisles, corridors, and exits free of obstruction in case of emergency. | D | Deficient, Provider has date of correction (2024-08-05) |
| K0293 | Egress Deficiencies | Have properly located and lighted "Exit" signs. | D | Deficient, Provider has date of correction (2024-09-07) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | F | Deficient, Provider has date of correction (2024-09-09) |
| K0331 | Smoke Deficiencies | Construct fire resistant interior walls. | D | Deficient, Provider has date of correction (2024-08-16) |
| K0345 | Smoke Deficiencies | Have approved installation, maintenance and testing program for fire alarm systems. | F | Deficient, Provider has date of correction (2024-08-16) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2024-09-07) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | F | Deficient, Provider has date of correction (2024-08-05) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | F | Deficient, Provider has date of correction (2024-08-02) |
| K0753 | Miscellaneous Deficiencies | Have restrictions on the use of highly flammable decorations. | D | Deficient, Provider has date of correction (2024-08-08) |
| K0761 | Miscellaneous Deficiencies | To conduct inspection, testing and maintenance of fire doors by qualified individuals. | F | Deficient, Provider has date of correction (2024-08-02) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2024-09-09) |
| K0919 | Gas, Vacuum, and Electrical Systems Deficiencies | Meet requirements for the use of electrical equipment. | D | Deficient, Provider has date of correction (2024-08-07) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | Have proper medical gas storage and administration areas. | D | Deficient, Provider has date of correction (2024-08-02) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| F0550 | Resident Rights Deficiencies | Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights. | E | Deficient, Provider has date of correction (2024-09-07) |
| F0584 | Resident Rights Deficiencies | Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely. | E | Deficient, Provider has date of correction (2024-09-07) |
| F0645 | Resident Assessment and Care Planning Deficiencies | PASARR screening for Mental disorders or Intellectual Disabilities | D | Deficient, Provider has date of correction (2024-09-07) |
| F0655 | Resident Assessment and Care Planning Deficiencies | Create and put into place a plan for meeting the resident's most immediate needs within 48 hours of being admitted | D | Deficient, Provider has date of correction (2024-09-07) |
| F0656 | Resident Assessment and Care Planning Deficiencies | Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured. | E | Deficient, Provider has date of correction (2024-09-07) |
| F0657 | Resident Assessment and Care Planning Deficiencies | Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals. | D | Deficient, Provider has date of correction (2024-09-07) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | D | Deficient, Provider has date of correction (2024-09-07) |
| F0699 | Quality of Life and Care Deficiencies | Provide care or services that was trauma informed and/or culturally competent. | D | Deficient, Provider has date of correction (2024-09-07) |
| F0761 | Pharmacy Service Deficiencies | Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs. | E | Deficient, Provider has date of correction (2024-09-07) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | D | Deficient, Provider has date of correction (2024-09-07) |
| F0814 | Nutrition and Dietary Deficiencies | Dispose of garbage and refuse properly. | D | Deficient, Provider has date of correction (2024-09-07) |
| F0908 | Environmental Deficiencies | Keep all essential equipment working safely. | D | Deficient, Provider has date of correction (2024-09-07) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| E0006 | Emergency Preparedness Deficiencies | | F | Deficient, Provider has date of correction (2024-08-05) |
| E0024 | Emergency Preparedness Deficiencies | | F | Deficient, Provider has date of correction (2024-08-05) |
| E0029 | Emergency Preparedness Deficiencies | | F | Deficient, Provider has date of correction (2024-08-05) |
| K0163 | Construction Deficiencies | | F | Deficient, Provider has date of correction (2024-08-05) |
| K0211 | | | D | Deficient, Provider has date of correction (2024-08-05) |
| K0293 | Egress Deficiencies | | D | Deficient, Provider has date of correction (2024-09-07) |
| K0321 | Smoke Deficiencies | | F | Deficient, Provider has date of correction (2024-09-09) |
| K0331 | Smoke Deficiencies | | D | Deficient, Provider has date of correction (2024-08-16) |
| K0345 | Smoke Deficiencies | | F | Deficient, Provider has date of correction (2024-08-16) |
| K0353 | Smoke Deficiencies | | F | Deficient, Provider has date of correction (2024-09-07) |
| K0363 | Smoke Deficiencies | | F | Deficient, Provider has date of correction (2024-08-05) |
| K0712 | Miscellaneous Deficiencies | | F | Deficient, Provider has date of correction (2024-08-02) |
| K0753 | Miscellaneous Deficiencies | | D | Deficient, Provider has date of correction (2024-08-08) |
| K0761 | Miscellaneous Deficiencies | | F | Deficient, Provider has date of correction (2024-08-02) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | | F | Deficient, Provider has date of correction (2024-09-09) |
| K0919 | Gas, Vacuum, and Electrical Systems Deficiencies | | D | Deficient, Provider has date of correction (2024-08-07) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | | D | Deficient, Provider has date of correction (2024-08-02) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| F0584 | Resident Rights Deficiencies | Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely. | E | Deficient, Provider has date of correction (2023-06-24) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | E | Deficient, Provider has date of correction (2023-05-26) |
| F0695 | Quality of Life and Care Deficiencies | Provide safe and appropriate respiratory care for a resident when needed. | D | Deficient, Provider has date of correction (2023-05-16) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | E | Deficient, Provider has date of correction (2023-05-26) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| K0222 | Egress Deficiencies | Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. | F | Deficient, Provider has date of correction (2023-05-26) |
| K0232 | Egress Deficiencies | Have corridors or aisles that are unobstructed and are at least 8 feet in width. | D | Deficient, Provider has date of correction (2023-05-26) |
| K0293 | Egress Deficiencies | Have properly located and lighted "Exit" signs. | C | Deficient, Provider has date of correction (2023-06-14) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | C | Deficient, Provider has date of correction (2023-05-26) |
| K0345 | Smoke Deficiencies | Have approved installation, maintenance and testing program for fire alarm systems. | F | Deficient, Provider has date of correction (2023-06-14) |
| K0351 | Smoke Deficiencies | Install an approved automatic sprinkler system. | C | Deficient, Provider has date of correction (2023-05-26) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | C | Deficient, Provider has date of correction (2023-06-14) |
| K0372 | Smoke Deficiencies | Ensure smoke barriers are constructed to a 1 hour fire resistance rating. | D | Deficient, Provider has date of correction (2023-05-26) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | F | Deficient, Provider has date of correction (2023-05-26) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2023-05-26) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | Have proper medical gas storage and administration areas. | D | Deficient, Provider has date of correction (2023-05-26) |
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
| K0222 | Egress Deficiencies | | F | Deficient, Provider has date of correction (2023-05-26) |
| K0232 | Egress Deficiencies | | D | Deficient, Provider has date of correction (2023-05-26) |
| K0293 | Egress Deficiencies | | C | Deficient, Provider has date of correction (2023-06-14) |
| K0321 | Smoke Deficiencies | | C | Deficient, Provider has date of correction (2023-05-26) |
| K0345 | Smoke Deficiencies | | F | Deficient, Provider has date of correction (2023-06-14) |
| K0351 | Smoke Deficiencies | | C | Deficient, Provider has date of correction (2023-05-26) |
| K0353 | Smoke Deficiencies | | C | Deficient, Provider has date of correction (2023-06-14) |
| K0372 | Smoke Deficiencies | | D | Deficient, Provider has date of correction (2023-05-26) |
| K0712 | Miscellaneous Deficiencies | | F | Deficient, Provider has date of correction (2023-05-26) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | | F | Deficient, Provider has date of correction (2023-05-26) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | | D | Deficient, Provider has date of correction (2023-05-26) |