Dubuque Specialty Care
2935 Kaufmann Avenue, Dubuque, IA 52001 · Dubuque County · CCN 165228 · 5635560673
All ratings are CMS Five-Star ratings from the October 1, 2026 release. “Not rated” means CMS did not publish a rating for this facility in that release.
Facility facts (CMS record)
| Legal business name | Care Initiatives |
|---|---|
| Ownership type | Non profit - Corporation |
| Certified beds | 84 |
| Average residents per day | 48.3 |
| Provider type | Medicare and Medicaid |
| Certified since | 1994-05-01 |
| Chain | Care Initiatives (43 facilities nationally) |
| Changed ownership in last 12 months | No |
| Sprinklers in all required areas | Yes |
Staffing (CMS record, hours per resident per day)
| Total nurse staffing (adjusted) | 4.19044 |
|---|---|
| RN staffing (adjusted) | 0.82211 |
| Total nurse staffing (reported) | 3.19719 |
| Total nursing staff turnover | 62.3% |
| RN turnover | 62.5% |
| Administrators who left in the past year | 1 |
Penalties
| Date | Type | Fine | Payment denial |
|---|---|---|---|
| 2024-07-15 | Fine | $53,372 | |
| 2024-07-15 | Payment Denial | from 2024-08-07, 16 days |
How this facility's record has changed
CMS overall rating at each monthly data release, as published at the time. Points are releases, not survey dates.
| CMS release | Overall | Health inspection | Staffing | Quality measures | Total nurse staffing (hrs / resident / day, adjusted) | Nurse turnover |
|---|---|---|---|---|---|---|
| 2019-04-09 | 4 | 4 | 3 | 2 | 3.22129 | — |
| 2019-07-09 | 3 | 4 | 2 | 1 | 3.33531 | — |
| 2019-10-09 | 4 | 4 | 3 | 2 | 3.42286 | — |
| 2020-01-09 | 3 | 4 | 3 | 1 | 3.26953 | — |
| 2020-04-09 | 3 | 4 | 3 | 1 | 3.28162 | — |
| 2020-07-09 | 3 | 4 | 3 | 1 | 3.28162 | — |
| 2020-10-09 | 3 | 4 | 3 | 1 | 2.8524 | — |
| 2021-01-27 | 2 | 3 | 3 | 1 | 3.36244 | — |
| 2021-04-27 | 2 | 3 | 2 | 1 | 2.98268 | — |
| 2021-07-27 | 1 | 2 | 3 | 1 | 3.61165 | — |
| 2021-10-27 | 2 | 2 | 3 | 3 | 3.46881 | — |
| 2022-01-27 | 3 | 3 | 2 | 2 | 3.13885 | — |
| 2022-04-27 | 3 | 3 | 3 | 3 | 3.20456 | — |
| 2022-07-27 | 2 | 3 | 1 | 4 | 3.29065 | — |
| 2022-10-27 | 3 | 3 | 2 | 4 | 3.44518 | — |
| 2023-01-02 | 3 | 3 | 2 | 4 | 3.05306 | — |
| 2023-04-26 | 2 | 3 | 1 | 4 | 2.70119 | — |
| 2023-07-25 | 1 | 1 | 1 | 4 | 2.61027 | — |
| 2023-10-02 | 1 | 1 | 1 | 3 | 2.54545 | — |
| 2024-01-31 | 1 | 1 | 1 | 3 | 3.28722 | — |
| 2024-04-25 | 1 | 1 | 1 | 3 | 3.28722 | — |
| 2024-07-31 | 1 | 1 | 1 | 3 | 3.32394 | — |
| 2024-10-30 | 2 | 2 | 2 | 3 | 3.59148 | — |
| 2025-02-26 | 2 | 2 | 3 | 4 | 4.07675 | — |
| 2025-04-30 | 2 | 2 | 2 | 3 | 3.72457 | — |
| 2025-07-30 | 1 | 1 | 2 | 4 | 3.8782 | — |
| 2025-11-20 | 2 | 2 | 2 | 4 | 3.83483 | — |
| 2026-01-14 | 2 | 2 | 2 | 4 | 3.83483 | — |
| 2026-04-29 | 2 | 2 | 2 | 3 | 3.66393 | — |
| 2026-10-28 | 2 | 2 | 3 | 3 | 4.19044 | — |
Notable events in the record
CMS overall rating changed: 1 → 2 stars
CMS overall rating changed: 2 → 1 stars
CMS overall rating changed: 1 → 2 stars
Denial of payment for new admissions began (16 days)
Civil money penalty (fine) of $53,372 imposed
CMS abuse icon removed
CMS abuse icon added
CMS overall rating changed: 2 → 1 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 1 → 2 stars
CMS overall rating changed: 2 → 1 stars
CMS overall rating changed: 3 → 2 stars
CMS overall rating changed: 4 → 3 stars
CMS overall rating changed: 3 → 4 stars
CMS overall rating changed: 4 → 3 stars
Inspection citations (38)
Survey cycles on record: Cycle 1: health survey 2025-07-30 (8 health deficiencies), fire safety survey 2025-07-30 (2); Cycle 2: health survey 2024-07-15 (14 health deficiencies), fire safety survey 2024-07-15 (6); Cycle 3: health survey 2023-05-04 (1 health deficiencies), fire safety survey 2023-05-04 (7)
2025-07-30 — Health survey (Health): 8 citations, most severe scope/severity: F Complaint survey
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0644 | Resident Assessment and Care Planning Deficiencies | Coordinate assessments with the pre-admission screening and resident review program; and referring for services as needed. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0657 | Resident Assessment and Care Planning Deficiencies | Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0725 | Nursing and Physician Services Deficiencies | Provide enough nursing staff every day to meet the needs of every resident; and have a licensed nurse in charge on each shift. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0740 | Quality of Life and Care Deficiencies | Ensure each resident must receive and the facility must provide necessary behavioral health care and services. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0760 | Pharmacy Service Deficiencies | Ensure that residents are free from significant medication errors. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | D | Deficient, Provider has date of correction (2025-08-28) |
| F0865 | Administration Deficiencies | Have a plan that describes the process for conducting QAPI and QAA activities. | F | Deficient, Provider has date of correction (2025-08-28) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | D | Deficient, Provider has date of correction (2025-08-28) |
2025-07-30 — Fire safety survey (Fire Safety): 2 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2025-07-22) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | F | Deficient, Provider has date of correction (2025-07-22) |
2024-07-15 — Fire safety survey (Fire Safety): 6 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| E0039 | Emergency Preparedness Deficiencies | Conduct testing and exercise requirements. | F | Deficient, Provider has date of correction (2024-07-31) |
| E0041 | Emergency Preparedness Deficiencies | Implement emergency and standby power systems. | F | Deficient, Provider has date of correction (2024-07-30) |
| K0223 | Egress Deficiencies | Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. | E | Deficient, Provider has date of correction (2024-07-16) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | D | Deficient, Provider has date of correction (2024-07-16) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2024-08-05) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2024-08-23) |
2024-07-15 — Health survey (Health): 14 citations, most severe scope/severity: G Complaint survey
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0550 | Resident Rights Deficiencies | Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0580 | Resident Rights Deficiencies | Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.) that affect the resident. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0584 | Resident Rights Deficiencies | Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0623 | Resident Rights Deficiencies | Provide timely notification to the resident, and if applicable to the resident representative and ombudsman, before transfer or discharge, including appeal rights. | B | Deficient, Provider has date of correction (2024-08-06) |
| F0625 | Resident Rights Deficiencies | Notify the resident or the resident’s representative in writing how long the nursing home will hold the resident’s bed in cases of transfer to a hospital or therapeutic leave. | B | Deficient, Provider has date of correction (2024-08-06) |
| F0657 | Resident Assessment and Care Planning Deficiencies | Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0658 | Resident Assessment and Care Planning Deficiencies | Ensure services provided by the nursing facility meet professional standards of quality. | E | Deficient, Provider has date of correction (2024-08-06) |
| F0684 | Quality of Life and Care Deficiencies | Provide appropriate treatment and care according to orders, resident’s preferences and goals. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0686 | Quality of Life and Care Deficiencies | Provide appropriate pressure ulcer care and prevent new ulcers from developing. | G | Deficient, Provider has date of correction (2024-08-06) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0725 | Nursing and Physician Services Deficiencies | Provide enough nursing staff every day to meet the needs of every resident; and have a licensed nurse in charge on each shift. | E | Deficient, Provider has date of correction (2024-08-06) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | E | Deficient, Provider has date of correction (2024-08-06) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | D | Deficient, Provider has date of correction (2024-08-06) |
| F0919 | Environmental Deficiencies | Make sure that a working call system is available in each resident's bathroom and bathing area. | D | Deficient, Provider has date of correction (2024-08-06) |
2023-10-24 — Health survey (Health): 1 citation, most severe scope/severity: G Complaint survey
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | G | Deficient, Provider has date of correction (2023-12-04) |
2023-05-04 — Fire safety survey (Fire Safety): 7 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0223 | Egress Deficiencies | Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. | E | Deficient, Provider has date of correction (2023-05-11) |
| K0321 | Smoke Deficiencies | Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | E | Deficient, Provider has date of correction (2023-05-15) |
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | F | Deficient, Provider has date of correction (2023-05-11) |
| K0345 | Smoke Deficiencies | Have approved installation, maintenance and testing program for fire alarm systems. | F | Deficient, Provider has date of correction (2023-05-11) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2023-05-17) |
| K0511 | Services Deficiencies | Have properly installed electrical wiring and gas equipment. | D | Deficient, Provider has date of correction (2023-05-11) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2023-05-15) |
Deficiency descriptions, categories and scope/severity codes are reproduced from CMS records. Scope/severity runs A (least) to L (most severe); J, K and L indicate immediate jeopardy findings in the CMS coding system.