Fairacres Manor, Inc.
1700 18th Ave, Greeley, CO 80631 · Weld County · CCN 065211 · 9703533370
All ratings are CMS Five-Star ratings from the October 1, 2026 release. “Not rated” means CMS did not publish a rating for this facility in that release.
Facility facts (CMS record)
| Legal business name | Fairacres Manor, Inc |
|---|---|
| Ownership type | For profit - Limited Liability company |
| Certified beds | 116 |
| Average residents per day | 104.1 |
| Provider type | Medicare and Medicaid |
| Certified since | 1985-08-01 |
| Chain | Frontline Management (9 facilities nationally) |
| Changed ownership in last 12 months | No |
| Sprinklers in all required areas | Yes |
Staffing (CMS record, hours per resident per day)
| Total nurse staffing (adjusted) | 3.7434 |
|---|---|
| RN staffing (adjusted) | 0.86978 |
| Total nurse staffing (reported) | 3.68869 |
| Total nursing staff turnover | 35.2% |
| RN turnover | 21.7% |
| Administrators who left in the past year | 1 |
How this facility's record has changed
CMS overall rating at each monthly data release, as published at the time. Points are releases, not survey dates.
| CMS release | Overall | Health inspection | Staffing | Quality measures | Total nurse staffing (hrs / resident / day, adjusted) | Nurse turnover |
|---|---|---|---|---|---|---|
| 2019-04-09 | 4 | 4 | 4 | 3 | 4.2394 | — |
| 2019-07-09 | 5 | 4 | 5 | 3 | 4.62444 | — |
| 2020-01-09 | 4 | 4 | 4 | 3 | 4.15886 | — |
| 2020-04-09 | 5 | 4 | 5 | 3 | 4.18773 | — |
| 2020-07-09 | 5 | 4 | 5 | 3 | 4.18773 | — |
| 2020-10-09 | 3 | 2 | 5 | 3 | 4.32747 | — |
| 2021-01-27 | 4 | 3 | 4 | 4 | 3.62006 | — |
| 2021-04-27 | 4 | 3 | 3 | 5 | 1.87648 | — |
| 2021-07-27 | 5 | 3 | 5 | 5 | 4.39556 | — |
| 2021-10-27 | 5 | 3 | 5 | 5 | 4.35227 | — |
| 2022-01-27 | 5 | 3 | 4 | 5 | 3.98606 | — |
| 2022-04-27 | 5 | 3 | 4 | 5 | 3.96337 | — |
| 2022-07-27 | 4 | 3 | 4 | 5 | 4.22675 | — |
| 2022-10-27 | 4 | 3 | 4 | 5 | 3.99926 | — |
| 2023-01-02 | 4 | 3 | 4 | 5 | 3.90657 | — |
| 2023-04-26 | 4 | 3 | 4 | 5 | 4.18775 | — |
| 2023-07-25 | 3 | 3 | 4 | 4 | 3.98844 | — |
| 2023-10-02 | 4 | 3 | 4 | 5 | 3.84731 | — |
| 2024-01-31 | 2 | 3 | 1 | 4 | — | — |
| 2024-04-25 | 2 | 3 | 1 | 4 | — | — |
| 2024-07-31 | 3 | 3 | 3 | 4 | 4.10191 | — |
| 2024-10-30 | 3 | 3 | 3 | 4 | 4.15827 | — |
| 2025-02-26 | 4 | 3 | 3 | 5 | 4.1582 | — |
| 2025-04-30 | 4 | 3 | 3 | 5 | 4.13869 | — |
| 2025-07-30 | 5 | 4 | 5 | 5 | 4.23004 | — |
| 2025-11-20 | 5 | 4 | 5 | 4 | 4.08127 | — |
| 2026-01-14 | 5 | 4 | 5 | 4 | 4.08127 | — |
| 2026-04-29 | 4 | 4 | 4 | 4 | 3.99919 | — |
| 2026-10-28 | 3 | 4 | 4 | 1 | 3.7434 | — |
Notable events in the record
CMS overall rating changed: 4 → 3 stars
CMS overall rating changed: 5 → 4 stars
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 3 → 4 stars
Ownership type changed: For profit - Corporation → For profit - Limited Liability company
CMS overall rating changed: 2 → 3 stars
CMS overall rating changed: 4 → 2 stars
CMS overall rating changed: 3 → 4 stars
CMS overall rating changed: 4 → 3 stars
CMS overall rating changed: 5 → 4 stars
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 3 → 4 stars
CMS overall rating changed: 5 → 3 stars
CMS overall rating changed: 4 → 5 stars
CMS overall rating changed: 5 → 4 stars
CMS overall rating changed: 4 → 5 stars
Inspection citations (36)
Survey cycles on record: Cycle 1: health survey 2024-06-06 (3 health deficiencies), fire safety survey 2024-06-06 (14); Cycle 2: health survey 2020-02-13 (8 health deficiencies), fire safety survey 2020-02-13 (3); Cycle 3: health survey 2019-02-21 (6 health deficiencies), fire safety survey 2019-02-21 (2)
2024-06-06 — Health survey (Health): 3 citations, most severe scope/severity: F Complaint survey
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0803 | Nutrition and Dietary Deficiencies | Ensure menus must meet the nutritional needs of residents, be prepared in advance, be followed, be updated, be reviewed by dietician, and meet the needs of the resident. | E | Deficient, Provider has date of correction (2024-06-23) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | F | Deficient, Provider has date of correction (2024-06-23) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | D | Deficient, Provider has date of correction (2024-06-23) |
2024-06-06 — Fire safety survey (Fire Safety): 14 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0293 | Egress Deficiencies | Have properly located and lighted "Exit" signs. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | F | Deficient, Provider has date of correction (2024-09-03) |
| K0331 | Smoke Deficiencies | Construct fire resistant interior walls. | E | Deficient, Provider has date of correction (2024-09-03) |
| K0345 | Smoke Deficiencies | Have approved installation, maintenance and testing program for fire alarm systems. | F | Deficient, Provider has date of correction (2024-09-03) |
| K0346 | Smoke Deficiencies | Follow proper procedures when the fire alarm was out of service for more than 4 hours. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0353 | Smoke Deficiencies | Inspect, test, and maintain automatic sprinkler systems. | F | Deficient, Provider has date of correction (2024-09-03) |
| K0354 | Smoke Deficiencies | Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0541 | Services Deficiencies | Install properly constructed and protected linen or trash chutes. | E | Deficient, Provider has date of correction (2024-09-03) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0914 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing. | F | Deficient, Provider has date of correction (2024-09-03) |
| K0918 | Gas, Vacuum, and Electrical Systems Deficiencies | Have generator or other power source capable of supplying service within 10 seconds. | F | Deficient, Provider has date of correction (2024-09-03) |
| K0920 | Gas, Vacuum, and Electrical Systems Deficiencies | Ensure proper usage of power strips and extension cords. | D | Deficient, Provider has date of correction (2024-09-03) |
| K0923 | Gas, Vacuum, and Electrical Systems Deficiencies | Have proper medical gas storage and administration areas. | F | Deficient, Provider has date of correction (2024-09-03) |
2020-02-13 — Health survey (Health): 8 citations, most severe scope/severity: G
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0558 | Resident Rights Deficiencies | Reasonably accommodate the needs and preferences of each resident. | D | Deficient, Provider has date of correction (2020-03-13) |
| F0604 | Freedom from Abuse, Neglect, and Exploitation Deficiencies | Ensure that each resident is free from the use of physical restraints, unless needed for medical treatment. | D | Deficient, Provider has date of correction (2020-03-13) |
| F0686 | Quality of Life and Care Deficiencies | Provide appropriate pressure ulcer care and prevent new ulcers from developing. | G | Deficient, Provider has date of correction (2020-03-13) |
| F0689 | Quality of Life and Care Deficiencies | Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents. | D | Deficient, Provider has date of correction (2020-03-13) |
| F0759 | Pharmacy Service Deficiencies | Ensure medication error rates are not 5 percent or greater. | E | Deficient, Provider has date of correction (2020-03-13) |
| F0761 | Pharmacy Service Deficiencies | Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs. | E | Deficient, Provider has date of correction (2020-03-13) |
| F0812 | Nutrition and Dietary Deficiencies | Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | F | Deficient, Provider has date of correction (2020-03-13) |
| F0880 | Infection Control Deficiencies | Provide and implement an infection prevention and control program. | F | Deficient, Provider has date of correction (2020-03-13) |
2020-02-13 — Fire safety survey (Fire Safety): 3 citations, most severe scope/severity: D
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | D | Deficient, Provider has date of correction (2020-04-30) |
| K0712 | Miscellaneous Deficiencies | Have simulated fire drills held at unexpected times. | D | Deficient, Provider has date of correction (2020-03-30) |
| K0911 | Gas, Vacuum, and Electrical Systems Deficiencies | Meet requirements for the installation and maintenance of electrical systems. | D | Deficient, Provider has date of correction (2020-03-12) |
2019-02-21 — Health survey (Health): 6 citations, most severe scope/severity: D
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| F0604 | Freedom from Abuse, Neglect, and Exploitation Deficiencies | Ensure that each resident is free from the use of physical restraints, unless needed for medical treatment. | D | Deficient, Provider has date of correction (2019-03-28) |
| F0609 | Freedom from Abuse, Neglect, and Exploitation Deficiencies | Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities. | D | Deficient, Provider has date of correction (2019-03-21) |
| F0610 | Freedom from Abuse, Neglect, and Exploitation Deficiencies | Respond appropriately to all alleged violations. | D | Deficient, Provider has date of correction (2019-03-21) |
| F0636 | Resident Assessment and Care Planning Deficiencies | Assess the resident completely in a timely manner when first admitted, and then periodically, at least every 12 months. | D | Deficient, Provider has date of correction (2019-03-21) |
| F0657 | Resident Assessment and Care Planning Deficiencies | Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals. | D | Deficient, Provider has date of correction (2019-03-28) |
| F0695 | Quality of Life and Care Deficiencies | Provide safe and appropriate respiratory care for a resident when needed. | D | Deficient, Provider has date of correction (2019-03-21) |
2019-02-21 — Fire safety survey (Fire Safety): 2 citations, most severe scope/severity: F
| Tag | Category | Deficiency (as cited by CMS) | Scope / severity | Corrected |
|---|---|---|---|---|
| K0324 | Smoke Deficiencies | Provide properly protected cooking facilities. | F | Deficient, Provider has date of correction (2019-04-15) |
| K0363 | Smoke Deficiencies | Install corridor and hallway doors that block smoke. | F | Deficient, Provider has date of correction (2019-04-15) |
Deficiency descriptions, categories and scope/severity codes are reproduced from CMS records. Scope/severity runs A (least) to L (most severe); J, K and L indicate immediate jeopardy findings in the CMS coding system.